Monitair Chevron Retro-fit Fume Hood Airflow Monitor

£199.00

SKU: CHV-001 Categories: , ,

Description

Monitair Chevron Retro-fit Fume Hood Airflow Monitor

How do you take the hassle out of fitting LEV airflow indicators?

  • The HSE now recommends that airflow indicators should be fitted to all Local Exhaust Ventilation (LEV) systems.*
  • Inspection companies check that airflow indicators are fitted to all LEV extraction points as part of the compulsory Thorough Examination and Test (TExT).
  • Fitting airflow indicators greatly improves the safety of personnel using an LEV.

… but fitting them can be a hassle.

The problem is that most airflow indicators are generic mechanical pressure gauges, and are supplied with a preset measurement range. They often have fixed green and red regions, but the significance of the region boundaries is not always clear.

Using these time-proven devices is perfectly acceptable, but a successful installation requires you to

  1. set up and balance the LEV system,
  2. measure the static pressure at each exhaust point
  3. order the correct gauge for each point
  4. wait for the gauges to arrive
  5. fit the correct gauge to the correct point.

… which is complex, repetitive, time-consuming and TEDIOUS.

What can you do to make this easier and quicker?

At Monitair, we believed that the best way to reassure LEV users that their environment is safe to work in, was to design and manufacture an airflow indicator specifically for fitting to LEV systems. It should be quick and easy to set up as the LEV is being installed and commissioned, or just as easily retro-fitted to existing installations.

The result is the Chevron, a user-friendly, highly visible electronic airflow indicator, which instantly shows if the LEV is working as it should.

Chevron airflow indicator showing good airflow

Chevron airflow indicator showing low airflow

Our aim has been to make the Chevron

  • Easier to FIT
  • Easier to CALIBRATE
  • Easier to USE
  • Easier to AFFORD

Easier to Fit. The Chevron can be fitted either to the duct or to a suitable surface or structure using banding, self-tapping screws, nuts and bolts or any way you prefer. It only weighs 125g, so lightweight fittings can be used.

Easier to calibrate. You only need one type of Chevron. You don’t need to know the static pressure inside the duct. As long as it’s sufficient to pull air at a high enough extraction speed, the Chevron will monitor the pressure and react accordingly. A simple calibration procedure is carried out, with the unit in situ, when you know the airflow is correct. It’s a breeze. For more details on Installation and Calibration, visit the InstallationPage.

Easier to Use. The Chevron is highly visible and attention-grabbing, and has a continuously moving display to indicate either adequate or insufficient airflow. The user has no difficulty reading the display with just a glance. If the fan fails, or the duct gets damaged, or if a blockage reduces the duct airflow, the Chevron will tell you – unambiguously.

Easier to Afford. Constantly measuring and remeasuring static pressure as the LEV is commissioned and balanced is an arduous and time-consuming task. Changes to the system, such as adding in new hoods, or increasing or balancing existing air velocities requires repeating the process, taking further precious time. Because the Chevron can be re-calibrated quickly and as often as you need, you save time and money.

* ‘Controlling airborne contaminants at work: A guide to local exhaust ventilation’   is an HSE publication – commonly know as HSG258 – that sets out guidelines for designers and users of LEV. One recommendation set out in this document is that ‘Employers need to ensure that LEV systems continue to work properly. There are several ways of checking this […] the simplest way is probably to use an airflow indicator. […] This will give the operator a simple indication that the hood is working properly